Showing 1 - 20 out of 22
Year:
- PEXIT profile projector + storage foot T&O SW3000 2-axis display 116X60X160cm 10x magnificationYear:
- NIKON 6C-2 Profile Projector + storage stand 50x65x165cm 10x and 20x magnificationYear:
-MITUTOYO 302 Profile Projector + 2-axis Visu 55x70x110cm 10x and 20x magnificationYear: 2001
DESCRIPTION The SUSS PA200 Semiautomatic Probe System is very stable, modular and flexible probe systems for wafers and substrates up to 200 mm (8). The standard ProberBench® Operating System provides ease of use and programmed automation for the most demanding analytical applications. The modular design is effective, versatile and has a defined upgrade path. FEATURES AND BENEFITS Application flexibility …Year:
Screen Diameter: 300mm dia. Magnification: 10x, 20x, 50xYear: 2019
Coordinate machine (CMM) enabling spatial measurements of complex elements. Basic parameters: 1. Model CMM Global S BLUE 12.22.10 2. Manufacturer - Hexagon 3. Serial number - Will be completed tomorrow 4. Year of production - 2019 5. Condition - Brand new machine, never working, never used. 6. Basic parameters: - CNC controller with the "Fly" function - Advanced CLIMA temperature …Year:
The Keysight (Agilent) PNA-L vector network analyzer is a member of the PNA series network analyzer platform and is designed for your general-purpose network analysis needs. Advanced features help you work quickly, easily, and accurately. With the same firmware as the PNA, the PNA-L offers the perfect balance of value and performance. PNA-L provides efficiency and flexibility in both manufacturing …Year: 2008
Benefits Unique combination of ground microphone and tracer gas detector Everything included in a set (control unit, ground microphone, H2 sensor) Highest location precision due to visualisation of up to nine measuring points (gas concentration / sound) Highest sensitivity for tracer gas detection With the modern series of Hydrolux equipment HL 500 H2 and HL 5000 H2, you can find …Year:
The Keysight 4156C Precision Semiconductor Parameter Analyzer is a highly accurate laboratory bench top solution for advanced device characterization. The 41501B Expander extends your capabilities to 1A/200V, and add a low noise ground unit and dual pulse generators on the 4156C General features -Highly accurate laboratory bench top parameter analyzer for advanced device characterization -4x High-resolution SMU, 2xVSU and 2xVMU …Year: 1995
Motor parameters tester Vogelsang Benning Geblaesemotoren-Pruefsystem. The device is used to automatically measure the parameters of various engines, produced on automatic lines, but it can also be used to measure individual motors. At present, the device is adapted to measure commutator motors for vacuum cleaners, so it has an automatic function of measuring parameters with open and closed air inlet, …Year:
XYZ Translation Stage Specification: - Mechanically Compatible with Karl Suss Micro Cascade Prober Station - Class 100 (ISO 5) Cleanroom Compatible - Fine Micrometer Movement - Locking Screw on Stages Probe Arm CascadeMicro-101268 This probe mount allows 5 degrees of tilt and the Z axis can rotate left and right 2 degrees. There is two thumb screws at the top …Year:
The SUSS PH250HF is specially designed to meet the strict demands of high frequency probing. Its rigid design is however also useful for special requirements in analytical and production probing such as holding large area detectors for optoelectronics applications. The PH250HF has a travel range of 25mm on both the X and Y axis, and 10mm in Z. All movement …Year:
MITUTOYO - BRTA916 - softver: MCOSMOS v4.1 - X axis: 900 mm - Y axis: 1600 mm - Z axis: 600 mm - probe and associated controller replaced in: 2019 - new joystick from 2020Year: 2016
- ZEISS O-SELECT digital measuring projector Measurement range (Field of View): X = 114 mm, Y = 91.5 mm Maximum component height = 65mm Length measurement deviation according to ISO 10360-7: 2011 MPE_EB XY (2D) (OT) = (4.5 + L / 100) μm Permissible temperature range for specifications 18-22 ° C - Megapixel camera with CAA corrected optics - Integrated …Year:
The TP03500 Series ThermoChuck System is a revolutionary high-performance platform providing exceptional flatness, parallelism, mechanical and thermal stability over a wide temperature range for the high precision testing of wafers at the wafer probing station. The chuck design is based on new, patented1 technologies from Temptronic Corporation. The TP03500 System consists of a low noise controller; a temperature-controlled vacuum chuck …Year:
Temptronic ThermoChucks are conductive heating and cooling systems for wafer testing at temperature. Its primary use is for wafer testing in Probe Stations. It is connected to Temptronic TP03010B controller. Temptronic TP03010B advanced ThermoChuck Design minimizes low stray capacitance and high electrical resistance to ground, superior Surface Electrical Isolation: >109 Ohms at 500 VDC between surface and ground at +25°C. …Year:
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principle of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected. The GGB Industries, Inc., line of calibration substrates is such a standard. Each …Year:
The GGB Industries, Inc., MODEL 40A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 40A achieves an insertion loss of less than 0.8 db and a return loss of greater than 18 db through 40 GHz. With its individually spring loaded, Beryllium-Copper, Tungsten, or Nickel tips, the Model 40A provides reliable contacts, …Year:
E3631A 80W Triple Output Power Supply, 6V, 5A & ±25V, 1A Keysight basic DC power supplies offer essential features for a tight budget. The triple output, 80 W, GPIB, E3631A provides small, compact size for bench use; low output ripple and noise; built-in measurements and basic programmable features with GPIB and RS232 interface. This clean and reliable supply is designed …Year:
The GGB Industries, Inc., MODEL 40A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 40A achieves an insertion loss of less than 0.8 db and a return loss of greater than 18 db through 40 GHz. With its individually spring loaded, Beryllium-Copper, Tungsten, or Nickel tips, the Model 40A provides reliable contacts, …